Abacus Lighting

Benefits


  • Wireless control simplifies operation
  • Centrally monitor and adjust power consumption
  • Dimmable in accordance with EN12193
  • Enables efficient planning of maintenance
  • No re-lamping costs
AAA-LUX AL Series LED

AAA-LUX AL Series LED

AL60, AL90 & AL180




IP65

Polar intensity diagrams

AAA-LUX AL360-45 Polar intesity diagram
AL60
Luminaire: AAA-LUX AL60 V6.0
Lamps: 1 x 8 LED SOURCES AAA-LUX

AAA-LUX - AL360-50 Polar intesity diagram
AL90
Luminaire: AAA-LUX AL90 V6.0
Lamps: 1 x 8 LED SOURCES AAA-LUX

AAA-LUX - AL360-55 Polar intesity diagram
AL180
Luminaire: AAA-LUX AL180 V6.0
Lamps: 1 x 8 LED SOURCES AAA-LUX


On this page: Dimensions | Lamp data

Additional AAA-LUX AL Series LED benefits


  • Instant startup
    • Light can be switched on and off as and when required, thus saving energy costs by reducing power consumption from wasted light.
  • Flexible dimming
    • Dimmable down to 10% for low use and security giving massive energy savings over conventional HID lamps.
  • Highly efficient optics
    • Increased system efficiency by reducing wasted light.

Technical Features


  • Controllable via smart devices, touch screen or wireless switch box
  • Mounting height 12-45m
  • Flexible bracket mount
  • Die cast aluminium polyester powder coated body with integrated heat sink
  • Lenses installed behind flat glass for maximum integrity of the lenses
  • Body and driver compartment sealed to IP65
  • High powered 1.5kW luminaire

Applications


  • Large area lighting
  • Large area car parks

Colours


Black Black

Lighting Distribution


  • The AAA-LUX AL-series of LED Luminaires offers a variety of distribution options to suit individual requirements (60°, 90° and 180°)

Dimensions (mm)


AAA-LUX - AL Series - Front viewAL Series front view
AAA-LUX - AL Series - Side viewAL Series - Side view
AAA-LUX - AL Series

 
AAA-LUX LED Floodlighting
 

AAA-LUX light management system


The system can be remotely monitored from a central location via computer. Wireless push button boxes or proximity sensors at entry gates can send information to the control box to activate the lights or alternatively smart devices can be used to give the same control. These signals are fed into the system and will activate the desired pre-programmed lighting scenes. In case of emergency, all lights can be switched to maximum at the central console. The facility manager can analyse the energy consumption of the system, and optimize between lighting level and energy costs. With a remote access module, an installer can access the system and inspect the luminaires and light management system. Based on luminaire data, maintenance can be scheduled.

AAA-LUX light management system

Easy replacement


  • Direct 400VAC connection
  • Wireless control
  • No complicated bracketry required

Electrically the luminaire will be connected to existing 400 VAC electrical installations. Even the existing light switches can remain in place.

However, in case of new installation, cabling costs are significantly lower. First, the product has no in-rush of start-up current, resulting in a much simpler cabling lay-out and also, fuses can have a lower rating. Secondly, with the wireless control of the luminaires no extra control cabling is needed.

Energy saving - Total-cost-of-ownership


  • Dimmed to the right level
  • Switched on when needed
  • Short ROI

Conventional luminaires are based on Metal Halide (MH) or High Pressure Sodium (HPS) lamps. These sources have a start-up and cooling period and cannot be dimmed. Over lifetime these lamps suffer from significant lumen depreciation, which means that new installations over-illuminate the area every night by approximately 40%. Even areas with no activity, but camera surveillance only, are illuminated at full power with MH or HPS light sources.

With the AAA-LUX lighting management system luminaires are set at the requested illumination level. Areas with no human activities are dimmed to camera level, increasing energy savings above 70%. Beside this, the projected 15 year lifetime reduces lamp replacements costs as well. In many cases, our TCO model calculates breakeven times below 3 years.


  Lamp Watts & Power consumption
(0-90% dimming)
Voltage output Max. current Power factor
(at max. power)
Colour temp. Colour rendering (Ra) Weight (kg) Distribution (deg)
AL60
AL90
AL180
1500W (100%)
200W (10%)
400Vac ≈4.5A >0.98 5200K >80 <27 60, 90, 180

All dimensions are in mm.