Conical columns give a real design orientated feel to your scheme, whether in steel with a painted finish or aluminium. And our conical columns come in a range between 4m-8m with head capacity between 10kg and 50kg.
Conical 4-8m Conical steel

Conical

4-8m Conical steel




Download PDF

Flange plate

TYPE 0
FA000G Bolts/cross brace M16 x 500mm
FC020 Template

TYPE 0 - FA000G Bolts/cross brace M16 x 500mm - FC020 Template
TYPE 1
FA001G Bolts/cross brace M20 x 500mm
FC021 Template

TYPE 1 - FA001G Bolts/cross brace M20 x 500mm - FC021 Template
TYPE 2
FA002G Bolts/cross brace M24 x 600mm
FC022 Template

TYPE 2 - FA002G Bolts/cross brace M24 x 600mm - FC022 Template

Brackets

Luminaires are typically post top mounted. If a bracket is required, contact the Abacus sales office.

All dimensions are in mm.

On this page: Column Dimensions | Mounting Details

Features
  • Designed to EN40
  • Hot dip galvanised to BS EN ISO 1461:2009

Accessories
  • ELSAB1/6A - Single fuse cut-out, 6A, loop in/out (not fitted)
  • ELSAB12/6A - Twin fuse cut-out, 6A, loop in/out (not fitted)


Column Dimensions
Column Dimensions
Conical - Fixed Columns

Technical data for columns & masts
The performance data for columns and masts gives their basic technical attributes only. The technical performance of a column or mast will be affected by local site conditions (terrain type, distance to sea, site altitude, windspeed) and the headload being carried.

Please Contact the Abacus Technical team to confirm the suitability of a column or mast for your application.


Root Mounted

Product Code Height

Height
AFT

TD
AFB

GD
BD

BD
z

z
Max. Head Capacity
Post Top (PT) or Side Entry (SE)
(kg)
Door Opening
Door
Opening
Weight (kg)
Weight (kg)
OTM (kNm)

OTM (kNm)
Shear (kN)

Shear (kN)
Min. Concrete Diameter*

Min. Concrete Diameter*
CS040 4m 60 107 114 600 35 (PT) 200 x 75 32 4.3 1.2 1217
CS050 5m 60 119 127 800 35 (PT) 300 x 85 44 4.9 1.2 594
CS051 5m 76 134 144 800 50 (PT) 10 (SE) 300 x 85 48 7.0 1.6 540
CS060 6m 60 131 142 1000 35 (PT) 300 x 85 53 6.5 1.4 408
CS061 6m 76 146 158 1000 50 (PT) 10 (SE) 300 x 85 72 8.8 1.7 543
CS081 8m 76 169 183 1200 50 (PT) 12 (SE) 600 x 115 102 12.5 2.0 446
* Root concrete diameter based on poor soil or better, min. 230kN/m2

Flange Plate Mounted

Product Code Height

Height
TD

TD
GD

GD
Max. Head Capacity
Post Top (PT) or Side Entry (SE)
(kg)
Door Opening
Door
Opening
Flange Plate
Flange Plate
Weight
Weight (kg)
OTM (kNm)

OTM (kNm)
Shear (kN)

Shear (kN)
Concrete Dimension*

Concrete
Dimension*
CS040/FP 4m 60 107 35 (PT) 200 x 75 Type 0 32 4.3 1.2 750 x 800
CS050/FP 5m 60 119 35 (PT) 300 x 85 Type 0 44 4.9 1.2 750 x 800
CS051/FP 5m 76 134 50 (PT) 10 (SE) 300 x 85 Type 1 48 7.0 1.6 750 x 900
CS060/FP 6m 60 131 35 (PT) 300 x 85 Type 1 53 6.5 1.4 750 x 900
CS061/FP 6m 76 146 50 (PT) 10 (SE) 300 x 85 Type 1 72 8.8 1.7 900 x 950
CS081/FP 8m 76 169 50 (PT) 12 (SE) 600 x 115 Type 2 102 12.5 2.0 950 x 1100
*Concrete dimension based on a minimum ground bearing pressure of 15OkN/m2, (S = square dimension, H = depth)