Abacus Lighting
When you need a heavy duty lighting column that you can trust, our engineered structures are second to none. In a range from 5m-12m you will find the spec you need here.
Heavy duty 5-12m Tubular steel

Heavy duty

5-12m Tubular steel




Download PDF

Flange plate

TYPE 1
FA001G Bolts/cross brace M20 x 500mm
FC021 Template

TYPE 1 - FA001G Bolts/cross brace M20 x 500mm - FC021 Template
TYPE 2
FA002G Bolts/cross brace M24 x 600mm
FC022 Template

TYPE 2 - FA002G Bolts/cross brace M24 x 600mm - FC022 Template
TYPE 3
FA003G Bolts/cross brace M30 x 800mm
FC003 Template

TYPE 3 - FA003G Bolts/cross brace M30 x 800mm - FC003 Template
All dimensions are in mm.

On this page: Column Dimensions | Mounting Details | Column Headload Capacity

Features
  • Designed to EN40
  • Hot dip galvanised to BS EN ISO 1461:2009
  • Manufactured in steel tube to EN10210

Accessories
  • ELSAB1/6A - Single fuse cut-out, 6A, loop in/out (not fitted)
  • ELSAB12/6A - Twin fuse cut-out, 6A, loop in/out (not fitted)


Column Dimensions
Column Dimensions
Heavy Duty - Fixed Columns

Technical data for columns & masts
The performance data for columns and masts gives their basic technical attributes only. The technical performance of a column or mast will be affected by local site conditions (terrain type, distance to sea, site altitude, windspeed) and the headload being carried.

Please Contact the Abacus Technical team to confirm the suitability of a column or mast for your application.


Root Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
z

z
Door Opening
Door
Opening
Weight
Weight (kg)
OTM (kNm)
OTM (kNm)
Shear (kN)
Shear (kN)
Min. Concrete Diameter*
Min. Concrete
Diameter*
TB058 5m 168 114 3675 1250 1000 600 x 115 59 9.1 2.1 1088
TB068 6m 168 114 4660 1250 1000 600 x 115 67 9.0 1.8 556
TB088/H 8m 194 114 6630 1250 1200 600 x 115 103

13.0

2.2 467
TB108/H/SP 10m 194 140/127 8600 1250 1500 600 x 115 158 19.5 2.5 358
TB128/H/SP 12m 219 168/152 9840 1750 1700 600 x 115 259 36.4 3.9 454
* Root concrete diameter based on poor soil or better, min. 230kN/m2
Supplied as standard with spigot, length 230mm

Flange Plate Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
Door Opening
Door
Opening
Flange Plate
Flange Plate
Weight
Weight (kg)
otm
OTM (kNm)
Shear
Shear (kN)
Concrete Dimension*
Concrete Dimension*
TB058/FP 5m 168 114 3675 1250 600 x 115 Type 1 75 9.1 2.1 900 x 950
TB068/FP 6m 168 114 4660 1250 600 x 115 Type 2 78 9.0 1.8 900 x 950
TB088/H/FP 8m 194 114 6630 1250 600 x 115 Type 2 110 13.0 2.2 950 x 1100
TB108/H/FP/SP 10m 194 140/127 8600 1250 600 x 115 Type 2 158 19.5 2.5 1050 x 1200
TB128/H/FP/SP 12m 219 168/152 9840 1750 600 x 115 Type 3 269 36.4 3.9 1250 x 1300
*Concrete dimension based on a minimum ground bearing pressure of 15OkN/m2, (S = square dimension, H = depth)
Supplied as standard with spigot, length 230mm

Outreach & Floodlight Brackets

Height Projection Length Outreach Brackets
Single (S)
Single (S)

Double (D)
Double (D)
Spigot Lengths


/SP 230mm
/SP1 100mm
Floodlight Brackets
Floodlight Bracket    Floodlight Bracket    Floodlight Bracket
Single (S)
Overlap Fit
on Shaft
Double (D)
Flush Fit
on Spigot
Type/Bolt
Centres (mm)
Overlap Fit on Shaft
Overlap Fit
on Shaft
Flush Fit
on Spigot
Flush Fit
on Spigot
5m TB058 TB058/SP TB058 TB058/SP
0.30m PR6-03/S or /D PR7-03/S or /D Double (800) FL4/3 FL5/3
  0.50m PR6-05/S or /D PR7-05/S or /D Triple (800) FL4/5 FL5/5
6m TB068 TB068/SP TB068 TB068/SP
  0.30m PR6-03/S or /D PR7-03/S or /D* Double (800) FL4/3 FL5/3
  0.50m PR6-05/S or /D PR7-05/S or /D* Triple (800) FL4/5 FL5/5
8m TB088/H TB088/H/SP TB088/H TB088/H/SP

1.0m

PR6-10/S or /D PR7-10/S or /D Double (800) FL4/3 FL5/3
1.5m PR6-15/S or /D PR7-15/S or /D Triple (800) FL4/5 FL5/5
10m     TB108/H/SP     TB108/H/SP
1.5m - PR5-15/S or /D Double (800) - FL3/3
2.0m - PR5-20/S or /D Triple (800) - FL3/5
2.5m - PR5-25/S or /D 4-way (800) - FL3/7
12m     TB128/H/SP     TB128/H/SP
1.5m - PR8-15/S or /D Double (800) - FL7/3
2.0m - PR8-20/S or /D Triple (800) - FL7/5
2.5m - PR8-25/S or /D 4-way (800) - FL7/7

Column Headload Capacity (m2)

Based on UK rationalised wind loading factors for EN40
Product Code Lantern Mounting / Projection Max. Headload (kg) Light 396 kN/m² Medium 429 kN/m² Heavy 466 kN/m² Extra Heavy 576 kN/m²
TB058 Post Top 60 0.824 1.675 1.533 1.224
  0.50m Single Outreach 20 1.138 1.043 0.954 0.76
  0.75m Single Outreach 20 0.99 0.907 0.829 0.658
TB068 Post Top 75 1.301 1.19 1.084 0.857
  0.50m Single Outreach 20 0.903 0.825 0.751 0.592
  0.75m Single Outreach 20 0.793 0.723 0.658 0.516
TB088/H Post Top 100 0.838 0.764 0.696 0.553
  0.50m Single Outreach 20 0.866 0.799 0.735 0.59
  0.75m Single Outreach 20 0.659 0.608 0.558 0.45
TB108/H/SP Post Top 100 0.992 0.916 0.845 0.647
  1m Single Outreach 20 0.446 0.411 0.377 0.302
  1.5m Single Outreach 20 0.297 0.272 0.248 0.195
TB128/H/SP Post Top 100 1.653 1.495 1.344 1.007
  1m Single Outreach 20 0.428 0.394 0.362 0.29
  2m Single Outreach 20 0.363 0.332 0.302 0.235