Abacus Lighting
Our integral projection arm columns are perfectly suited to roadside or pathway applications. They help throw the light outwards from the column and maintain the accuracy of the lighting design.
Light duty with integral projection arm 5-6m Tubular steel

Light duty

with integral projection arm

5-6m Tubular steel




Download PDF

Flange plate

TYPE 0
FA000G Bolts/cross brace M16 x 500mm
FC020 Template

TYPE 0 - FA000G Bolts/cross brace M16 x 500mm - FC020 Template

Integral Projection Arm

Integral Projection Arm
All dimensions are in mm.

On this page: Column Dimensions | Mounting Details | Column Headload Capacity

Features
  • Designed to EN40
  • Hot dip galvanised to BS EN ISO 1461:2009
  • Manufactured in steel tube to EN10210

Accessories
  • ELSAB1/6A - Single fuse cut-out, 6A, loop in/out (not fitted)
  • ELSAB12/6A - Twin fuse cut-out, 6A, loop in/out (not fitted)


Column Dimensions
Column Dimensions
Light Duty - Fixed Columns

Technical data for columns & masts
The performance data for columns and masts gives their basic technical attributes only. The technical performance of a column or mast will be affected by local site conditions (terrain type, distance to sea, site altitude, windspeed) and the headload being carried.

Please Contact the Abacus Technical team to confirm the suitability of a column or mast for your application.


Root Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
z

z
Door Opening
Door
Opening
Weight
Weight (kg)
OTM (kNm)
OTM (kNm)
Shear (kN)
Shear (kN)
Min. Concrete Diameter*
Min. Concrete
Diameter*
TB0504 5m 140 76 3750 1250 800 500 x 100 43 5.0 1.3 607
TB0604 6m 140 76 4750 1250 1000 500 x 100

50

4.8 1.1 307
* Root concrete diameter based on poor soil or better, min. 230kN/m2

Flange Plate Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
Door Opening
Door
Opening
Flange Plate
Flange Plate
Weight
Weight (kg)
otm
OTM (kNm)
Shear
Shear (kN)
Concrete Dimension*
Concrete Dimension*
TB0504/FP 5m 140 76 3750 1250 500 x 100 Type 0 43 5.0 1.3 750 x 800
TB0604/FP 6m 140 76 4750 1250 500 x 100 Type 0 50 4.8 1.1 750 x 800
*Concrete dimension based on a minimum ground bearing pressure of 15OkN/m2, (S = square dimension, H = depth)
Supplied as standard with spigot, length 230mm

Column Headload Capacity (m2)

Based on UK rationalised wind loading factors for EN40
Product Code Lantern Mounting / Projection Max. Headload (kg) Light 396 kN/m² Medium 429 kN/m² Heavy 466 kN/m² Extra Heavy 576 kN/m²
TB0504 0.30 10 0.835 0.759 0.686 0.529
  0.75 10 0.651 0.591 0.534 0.41
TB0604 0.30 10 0.586 0.509 0.453 0.332
  0.75 10 0.474 0.421 0.371 0.263