Our medium duty range of columns are available in 5m-12m heights and a wide variety of finishes including anti-graffiti, galvanised and painted.
Medium Duty 5-12M Tubular Steel

Medium duty

5-12m Tubular steel




Download PDF

Flange plate

TYPE 1
FA001G Bolts/cross brace M20 x 500mm
FC021 Template

TYPE 1 - FA001G Bolts/cross brace M20 x 500mm - FC021 Template
TYPE 2
FA002G Bolts/cross brace M24 x 600mm
FC022 Template

TYPE 2 - FA002G Bolts/cross brace M24 x 600mm - FC022 Template
All dimensions are in mm.

On this page: Column Dimensions | Mounting Details | Column Headload Capacity

Features
  • Designed to EN40
  • Hot dip galvanised to BS EN ISO 1461:2009
  • Manufactured in steel tube to EN10210

Accessories
  • ELSAB1/6A - Single fuse cut-out, 6A, loop in/out (not fitted)
  • ELSAB12/6A - Twin fuse cut-out, 6A, loop in/out (not fitted)


Column Dimensions
Column Dimensions
Medium Duty - Fixed Columns

Technical data for columns & masts
The performance data for columns and masts gives their basic technical attributes only. The technical performance of a column or mast will be affected by local site conditions (terrain type, distance to sea, site altitude, windspeed) and the headload being carried.

Please Contact the Abacus Technical team to confirm the suitability of a column or mast for your application.


Root Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
z

z
Door Opening
Door
Opening
Weight
Weight (kg)
OTM (kNm)
OTM (kNm)
Shear (kN)
Shear (kN)
Min. Concrete Diameter*
Min. Concrete
Diameter*
TB051 5m 168 76 3675 1250 800 600 x 115 36 5.0 1.3 600
TB061 6m 168 89 4660 1250 1000 600 x 115 56 7.3 1.6 460
TB088 8m 168 114 6630 1250 1200 600 x 115 87

8.8

1.6 320
TB108/L/SP 10m 168 140/127 8600 1250 1500 600 x 115 129 13.6 1.9 250
TB128/L/SP 12m 194 168/152 9840 1750 1700 600 x 115 188 20.8 2.6 260
* Root concrete diameter based on poor soil or better, min. 230kN/m2
Supplied as standard with spigot, length 230mm

Flange Plate Mounted

Product Code Height

Height
OD1

OD1
OD2

OD2
x

x
y

y
Door Opening
Door
Opening
Flange Plate
Flange Plate
Weight
Weight (kg)
otm
OTM (kNm)
Shear
Shear (kN)
Concrete Dimension*
Concrete Dimension*
TB051/FP 5m 168 76 3675 1250 600 x 115 Type 1 43 5.0 1.3 750 x 800
TB061/FP 6m 168 89 4660 1250 600 x 115 Type 1 56 7.3 1.6 850 x 950
TB088/FP 8m 168 114 6630 1250 600 x 115 Type 2 102 8.8 1.6 900 x 950
TB108/L/FP/SP 10m 168 140/127 8600 1250 600 x 115 Type 2 136 13.6 1.9 950 x 1100
TB128/L/FP/SP 12m 194 168/152 9840 1750 600 x 115 Type 2 188 20.8 2.6 1050 x 1200
*Concrete dimension based on a minimum ground bearing pressure of 15OkN/m2, (S = square dimension, H = depth)
Supplied as standard with spigot, length 230mm

Outreach & Floodlight Brackets

Height Projection Length Outreach Brackets
Single (S)
Single (S)

Double (D)
Double (D)
Spigot Lengths


/SP 230mm
/SP1 100mm
Floodlight Brackets
Floodlight Bracket    Floodlight Bracket    Floodlight Bracket
Single (S)
Overlap Fit
on Shaft
Double (D)
Flush Fit
on Spigot
Type/Bolt
Centres (mm)
Overlap Fit on Shaft
Overlap Fit
on Shaft
Flush Fit
on Spigot
Flush Fit
on Spigot
5m TB051 TB051/SP+/SP1* TB051 TB05/SP
0.30m PR2-03/S or /D PR1-03/S Single FL1/1 FL0/1
  0.50m PR2-05/S or /D PR1-05/S Double (600) FL1/2 FL0/2
6m TB050 TB061/SP+/SP1* TB061 TB061/SP
  0.30m PR4-03/S or /D PR2-03/S or /D* Single FL2/1 FL1/1
  0.50m PR4-05/S or /D PR2-05/S or /D* Double (600) FL2/3 FL1/3
8m TB060 TB088/SP TB088 TB088/SP
0.50m PR6-05/S or /D PR7-05/S or /D Single FL4/1 FL5/1
1.0m PR6-10/S or /D PR7-10/S Double (800) FL4/3 FL5/3
10m     TB108/L/SP     TB108/L/SP
0.50m - PR5-05/S or /D Single - FL3/1
1.0m - PR5-10/S or /D Double (600) - FL3/2
1.5m - PR5-15/S or /D Double (800) - FL3/3
12m     TB128/L/SP     TB128/L/SP
0.50m - PR8-05/S or /D Single - FL7/1
1.0m - PR8-10/S or /D Double (600) - FL7/2
1.5m - PR8-15/S or /D Double (800) - FL7/3
2.0m - PR8-20/S or /D Triple (800) - FL7/5
*Outreach brackets series PR1 & PR2 below 0.50m projection fit onto 100mm spigot (/SP1). 0.50m + on standard 230mm spigot (/SP)

Column Headload Capacity (m2)

Based on UK rationalised wind loading factors for EN40
Product Code Lantern Mounting / Projection Max. Headload (kg) Light 396 kN/m² Medium 429 kN/m² Heavy 466 kN/m² Extra Heavy 576 kN/m²
TB051 Post Top 35 0.851 0.774 0.7 0.54
  0.50m Single Outreach 10 0.78 0.709 0.641 0.492
  0.75m Single Outreach 10 0.715 0.648 0.585 0.447
TB061 Post Top 50 0.959 0.872 0.79 0.613
  0.50m Single Outreach 12 0.984 0.815 0.74 0.576
  0.75m Single Outreach 12 0.785 0.715 0.648 0.502
TB088 Post Top 60

0.487

0.439 0.396 0.308
  0.50m Single Outreach 16 0.38 0.342 0.307 0.237
  0.75m Single Outreach 16 0.333 0.299 0.267 0.203
TB108/L/SP Post Top 75 0.581 0.536 0.496 0.365
  0.50m Single Outreach 16 0.457 0.421 0.387 0.285
  1m Single Outreach 16 0.366 0.335 0.307 0.22
TB128/L/SP Post Top 75 0.749 0.658 0.571 0.376
  1m Single Outreach 20 0.42 0.386 0.354 0.263
  1.5m Single Outreach 20 0.278 0.255 0.232 0.183