Straight tubular columns give a slim-line, clean aesthetic. They are great for a classic approach to architectural schemes.
Straight tubular 3-6m tubular Steel

Straight tubular

3-6m Tubular steel




Download PDF

Flange plate

TYPE 0
FA000G Bolts/cross brace M16 x 500mm
FC020 Template

TYPE 0 - FA000G Bolts/cross brace M16 x 500mm - FC020 Template

All dimensions are in mm.

On this page: Column Dimensions | Mounting Details

Features
  • Designed to EN40
  • Hot dip galvanised to BS EN ISO 1461:2009
  • Manufactured in steel tube to EN10210

Accessories
  • ELSAB1/6A - Single fuse cut-out, 6A, loop in/out (not fitted)
  • ELSAB12/6A - Twin fuse cut-out, 6A, loop in/out (not fitted)


Column Dimensions
Column Dimensions
Straight Tubular - Fixed Columns

Technical data for columns & masts
The performance data for columns and masts gives their basic technical attributes only. The technical performance of a column or mast will be affected by local site conditions (terrain type, distance to sea, site altitude, windspeed) and the headload being carried.

Please Contact the Abacus Technical team to confirm the suitability of a column or mast for your application.


Root Mounted

Product Code Height

Height
OD1

OD1
Internal Dimensions

Internal
Dimensions
Internal Dimensions

Internal
Dimensions
z

z
Door Opening
Door
Opening
Weight (kg)
Weight (kg)
Min. Concrete Diameter*
Min. Concrete
Diameter*
S030 3m 60 - - 600 - 16 400
S040 4m 60 - - 800 - 21 400
S040/114/FD 4m 114 60 84 800 380 x 65 38 500
S050 5m 60 - - 800 - 26 400
S050/114/FD 5m 114 60 84 800 380 x 65 48 500
S060 6m 76 - - 1000 - 38 400
S060/114/FD 6m 114 60 84 1000 380 x 65 58 500
* Root concrete diameter based on poor soil or better, min. 230kN/m2
Top reduction spigot available to suit lantern

Flange Plate Mounted

Product Code Height

Height
OD1

OD1
Internal Dimensions

Internal
Dimensions
Internal Dimensions

Internal
Dimensions
Door Opening
Door
Opening
Flange Plate
Flange Plate
Weight (kg)
Weight (kg)
Concrete Dimension*
Concrete
Dimension*
S030/FP 3m 60 - - - Type 0 21 650 x 750
S040/FP 4m 60 - - - Type 0 26 650 x 750
S040/114/FPFD 4m 114 60 84 380 x 65 Type 0 39 750 x 800
S050/FP 5m 60 - - - Type 0 31 650 x 750
S050/114/FPFD 5m 114 60 84 380 x 65 Type 0 49 750 x 800
S060/FP 6m 76 - - - Type 0 41 650 x 750
S060/114/FPFD 6m 114 60 84 380 x 65 Type 0 59 750 x 800
*Concrete dimension based on a minimum ground bearing pressure of 15OkN/m2, (S = square dimension, H = depth)
Top reduction spigot available to suit lantern